OneMiners★ Istaknuto✓ Provjereni prodavačProduljeno jamstvoPlaćanje na rateNa zalihi, brza isporukaAntminer T21 - 233 TH/sHosting kod njih od $0.0364/kWh, $118 mjesečnoŠalje se iz: United States · provjereno prije 24 h
Kalkulator iz našeg besplatnog widgeta: prema njemu se računa svaki povrat na ovoj stranici.
Prihod dnevno
$8.52
Struja dnevno
−$3.87
Hosting dnevno
—
Dobit dnevno
$4.65
Povrat uz $996
—
Zarada i povrat su procjene prema današnjim cijenama kovanica i težini mreže, prije naknada poola, hostinga i poreza. Mijenjaju se svaki dan. Nije financijski savjet.
Ljestvice koriste glavnu kovanicu algoritma (BTC za SHA-256, LTC + DOGE za Scrypt): male sporedne mreže danas mogu plaćati više po hashu, ali ne mogu primiti mnogo hashratea.
Bitmain Antminer T21 (233Th) je ASIC rudar tvrtke Bitmain za algoritam SHA-256, s 233 TH/s pri 4,427 W. Datum izlaska: veljača 2024.. Njegova učinkovitost od 19.0 J/TH blizu je medijana SHA-256 rudara koje pratimo (20.4 J/TH). Pri $0.036/kWh je 108. od 299 SHA-256 rudara po dnevnoj zaradi i zarađuje oko $4.65 dnevno rudareći BTC. Najbolja cijena na AsicProfitu je $996. Po današnjim brojkama isplatio bi se za oko 215 dana. S 75 dB mjesto mu je u rudarskom pogonu ili hosting centru.
Pitanja i odgovori 6
Pitajte o ovom mineru. Provjereni računi pitaju i odgovaraju, prodavači odgovaraju u ime svoje trgovine, a svaka objava se provjerava prije prikaza.
Yusuf D. · 26. lis 2026. · o drugoj verziji
T21 shows warning J1:2 and power voltage read failed. What does it mean?
AsicProfit SupportAsicProfit · 27. lis 2026.
It points to the power side: the control board could not read the supply voltage, and the miner restarts. Measure each phase under load, not just at idle, and check the PDU sockets and cable terminations, since loose pins at the back of the socket are a known cause. If all three phases are healthy, the power supply is the next suspect. A unit under warranty should go back to Bitmain or an authorised repair centre.
Felix W. · 22. lis 2026. · o drugoj verziji
Is the T21 three-phase? I only have single-phase 240V at home.
AsicProfit SupportAsicProfit · 24. lis 2026.
Yes, the standard T21 ships for 380-415V three-phase input, which surprises many buyers because most Antminers in this class are single-phase. Owners confirm it needed electrical upgrades and three-phase PDUs. A few hobbyists run modified T21s on single-phase power supplies at reduced wattage, but that is a do-it-yourself conversion outside the warranty. Check your supply before you order.
Lucas O. · 17. lis 2026. · o drugoj verziji
can i just pull the plug on a T21 to switch it off
AsicProfit SupportAsicProfit · 18. lis 2026.
Not on the T21. An owner reported that its three-phase connector is not designed to be pulled under load, and if neutral breaks before the live pins it can damage the cable and power supply. Switch it off at the breaker first, then unplug. Frequent hard power cycling is also hard on solder joints, so fix the cause of any overheating rather than repeatedly cutting power.
Mark J. · 15. lis 2026. · o drugoj verziji
Why is the T21 cheaper than the S21, and is it the better buy?
AsicProfit SupportAsicProfit · 15. lis 2026.
The T21 does 190 TH/s at 19 J/TH, while the air-cooled S21 does 200 TH/s at 17.5 J/TH. You pay less up front but more electricity per terahash, so the T21's margin shrinks faster when difficulty rises or the Bitcoin price falls. It also needs three-phase power. With cheap three-phase electricity it can make sense; otherwise compare both in the calculator on this page at your power price.
Dmitri V. · 29. ruj 2026. · o drugoj verziji
My T21 keeps overheating in summer and some boards now show 0 of 108 chips. Hardware or cooling?
AsicProfit SupportAsicProfit · 1. lis 2026.
It can be both. Owners report T21s struggling in hot containers, with corner chips running much hotter than the rest, and boards that lose chips after a restart. Check fans and intake temperature, reseat the hashboard and control board cables, and test boards one at a time. Repasting the heatsinks has helped several owners. Faulty PDU socket pins that drop a phase can also cause odd chip errors. Underclocking through the hottest months is a common workaround.
David C. · 28. ruj 2026. · o drugoj verziji
How loud is the T21 and how much heat does it put out?
AsicProfit SupportAsicProfit · 28. ruj 2026.
It is listed at about 75 dB, which is not suitable for a living space. Nearly all of its roughly 3,610 W becomes heat, about 12,300 BTU per hour, so the room needs strong ventilation or ducting for the exhaust. The listed operating range is 5 to 45°C, but owners advise keeping intake air well below the top of that range for long life.
Prijavite se provjerenim računom da biste postavili pitanje. Prijava