OneMiners★ Istaknuto✓ Provereni prodavacProdužena garancijaPlaćanje na rateNa zalihama, brza isporukaAntminer T21 - 233 TH/sHosting kod njih od $0.0364/kWh, $118 mesečnoŠalje se iz: United States · provereno pre 24 h
Kalkulator iz našeg besplatnog vidžeta: po njemu se računa svaki povraćaj na ovoj stranici.
Prihod dnevno
$8.52
Struja dnevno
−$3.87
Hosting dnevno
—
Dobit dnevno
$4.65
Povraćaj uz $996
—
Zarada i povraćaj su procene na osnovu današnjih cena kovanica i težine mreže, pre naknada pula, hostinga i poreza. Menjaju se svakog dana. Nije finansijski savet.
Rang-liste koriste glavnu kovanicu algoritma (BTC za SHA-256, LTC + DOGE za Scrypt): male sporedne mreže danas mogu da plaćaju više po hešu, ali ne mogu da prime mnogo hešrejta.
Bitmain Antminer T21 (233Th) je ASIC rudar kompanije Bitmain za algoritam SHA-256, sa 233 TH/s pri 4,427 W. Datum izlaska: februar 2024.. Njegova efikasnost od 19.0 J/TH je blizu medijane SHA-256 rudara koje pratimo (20.4 J/TH). Pri $0.036/kWh je 108. od 299 SHA-256 rudara po dnevnoj zaradi i zarađuje oko $4.65 dnevno rudareći BTC. Najbolja cena na AsicProfitu je $996. Po današnjim brojkama isplatio bi se za oko 215 dana. Sa 75 dB mesto mu je u rudarskom pogonu ili hosting centru.
Pitanja i odgovori 6
Pitajte o ovom majneru. Provereni nalozi pitaju i odgovaraju, prodavci odgovaraju u ime svoje prodavnice, a svaka objava se proverava pre prikaza.
Yusuf D. · 26. окт 2026. · o drugoj verziji
T21 shows warning J1:2 and power voltage read failed. What does it mean?
AsicProfit SupportAsicProfit · 27. окт 2026.
It points to the power side: the control board could not read the supply voltage, and the miner restarts. Measure each phase under load, not just at idle, and check the PDU sockets and cable terminations, since loose pins at the back of the socket are a known cause. If all three phases are healthy, the power supply is the next suspect. A unit under warranty should go back to Bitmain or an authorised repair centre.
Felix W. · 22. окт 2026. · o drugoj verziji
Is the T21 three-phase? I only have single-phase 240V at home.
AsicProfit SupportAsicProfit · 24. окт 2026.
Yes, the standard T21 ships for 380-415V three-phase input, which surprises many buyers because most Antminers in this class are single-phase. Owners confirm it needed electrical upgrades and three-phase PDUs. A few hobbyists run modified T21s on single-phase power supplies at reduced wattage, but that is a do-it-yourself conversion outside the warranty. Check your supply before you order.
Lucas O. · 17. окт 2026. · o drugoj verziji
can i just pull the plug on a T21 to switch it off
AsicProfit SupportAsicProfit · 18. окт 2026.
Not on the T21. An owner reported that its three-phase connector is not designed to be pulled under load, and if neutral breaks before the live pins it can damage the cable and power supply. Switch it off at the breaker first, then unplug. Frequent hard power cycling is also hard on solder joints, so fix the cause of any overheating rather than repeatedly cutting power.
Mark J. · 15. окт 2026. · o drugoj verziji
Why is the T21 cheaper than the S21, and is it the better buy?
AsicProfit SupportAsicProfit · 15. окт 2026.
The T21 does 190 TH/s at 19 J/TH, while the air-cooled S21 does 200 TH/s at 17.5 J/TH. You pay less up front but more electricity per terahash, so the T21's margin shrinks faster when difficulty rises or the Bitcoin price falls. It also needs three-phase power. With cheap three-phase electricity it can make sense; otherwise compare both in the calculator on this page at your power price.
Dmitri V. · 29. сеп 2026. · o drugoj verziji
My T21 keeps overheating in summer and some boards now show 0 of 108 chips. Hardware or cooling?
AsicProfit SupportAsicProfit · 1. окт 2026.
It can be both. Owners report T21s struggling in hot containers, with corner chips running much hotter than the rest, and boards that lose chips after a restart. Check fans and intake temperature, reseat the hashboard and control board cables, and test boards one at a time. Repasting the heatsinks has helped several owners. Faulty PDU socket pins that drop a phase can also cause odd chip errors. Underclocking through the hottest months is a common workaround.
David C. · 28. сеп 2026. · o drugoj verziji
How loud is the T21 and how much heat does it put out?
AsicProfit SupportAsicProfit · 28. сеп 2026.
It is listed at about 75 dB, which is not suitable for a living space. Nearly all of its roughly 3,610 W becomes heat, about 12,300 BTU per hour, so the room needs strong ventilation or ducting for the exhaust. The listed operating range is 5 to 45°C, but owners advise keeping intake air well below the top of that range for long life.