LeedMinerZvýraznené✓ Overený predajcaSkladom, rýchle doručenieAntminer S21j XP Hydro - 495 TH/sHosting u nich od $0.055/kWh, $238 mesačneOdosiela z: China · overené pred 4 h
✓ Na skladeNový
Najlepšia cena$5,198582 dní návratnosť · $10.50/TH
OneMinersZvýraznené✓ Overený predajcaPredĺžená zárukaPlatba na splátkySkladom, rýchle doručenieAntminer S21j XP Hydro - 495 TH/sHosting u nich od $0.0364/kWh, $158 mesačneOdosiela z: United States · overené pred 4 h
PCPrahaZvýraznené✓ Overený predajcaSecret easter egg: $50 off, if you digPredĺžená zárukaSkladom, rýchle doručenieAntminer S21j XP Hyd · 495 TH/s / Skladem, doručení 4–5 dní / DomaHosting u nich od $0.0368/kWh, $159 mesačneOdosiela z: Czechia · overené pred 10 h
✓ Na skladeNový
$6,819148,499 CZK · 764 dní návratnosť · $13.78/TH
Yesmining✓ Overený predajcaBITMAIN Antminer S21J XP HYD 495TH/s Bitcoin MinerHosting u nich od $0.07/kWh, $303 mesačneOdosiela z: China · overené práve teraz
EndlessMiningBitmain Antminer S21JXP Hyd 495Th/s 5940W - Bitcoin MinerHosting u nich od $0.08/kWh, $347 mesačneOdosiela z: United States · overené pred 15 h
Antminer Distribution Europe✓ Overený predajcaAntminer S21j XP Hyd (495 th/s)Hosting u nich od $0.065/kWh, $282 mesačneOdosiela z: Netherlands · overené pred 15 h
Intermine Solutions GmbH✓ Overený predajcaBitmain Antminer S21j XP Hydro (495TH) BitcoinHosting u nich od $0.077/kWh, $334 mesačneOdosiela z: Germany · overené pred 10 h
Hostingové sadzby so všetkým pre tento stroj s 5,940 W a zisk, ktorý ostane pri dnešnom výnose. Opýtajte sa hostingu, či lokalita berie stroje s vodným alebo imerzným chladením.
Odhady podľa dnešných cien mincí a obtiažnosti siete, po poplatku poolu, prevádzkovej dobe a hostingu vyššie, pred zdanením. Nejde o finančné poradenstvo.
Zisk pri $0.0364/kWh
Pri $0.036/kWh je Bitmain Antminer S21j XP Hyd (495Th) na 20. mieste z 299 strojov SHA-256 podľa denného zisku a zarobí zhruba $8.93 denne ťažbou BTC. Najlepšia cena na AsicProfit je $5,198. Pri dnešných hodnotách sa zaplatí zhruba za 582 dní. Údaje k , aktualizujú sa každých 15 minút.
Obdobie
Výnos
Elektrina
Zisk
Deň
$14.12
−$5.19
$8.93
Týždeň
$98.86
−$36.32
$62.53
Mesiac
$423.68
−$155.68
$268.00
Rok
$5,155
−$1,894
$3,261
Výnos vs. elektrina · 142.6 kWh denne · pri dnešnej cene a obtiažnosti BTC
Zisková až do$0.099/kWhCena elektriny pre nulový zisk
Cena BTC pre nulový zisk$22,387O 63 % pod dnešnou cenou
Zisk podľa kryptomeny
Každá kryptomena, ktorú tento miner dokáže ťažiť, pri dnešných cenách a obtiažnosti · $0.0364/kWh
Rebríčky používajú hlavnú kryptomenu algoritmu (BTC pre SHA-256, LTC + DOGE pre Scrypt): malé vedľajšie siete môžu dnes platiť viac za hash, ale veľa hashrate neuniesú.
Bitmain Antminer S21j XP Hyd (495Th) je ASIC ťažobný stroj od Bitmain pre algoritmus SHA-256 s výkonom 495 TH/s pri 5,940 W. Uvedený na trh: marec 2026. So spotrebou 12.0 J/TH je o 41 % úspornejší než medián strojov SHA-256, ktoré sledujeme (20.4 J/TH). Pri $0.036/kWh je na 20. mieste z 299 strojov SHA-256 podľa denného zisku a zarobí zhruba $8.93 denne ťažbou BTC. Najlepšia cena na AsicProfit je $5,198. Pri dnešných hodnotách sa zaplatí zhruba za 582 dní. Je chladený vodou (hydro), takže namiesto ventilátorov potrebuje chladiaci okruh a suchý chladič.
Pooly, ktoré nachádzajú bloky
Najväčšie pooly pre mince, ktoré toto zariadenie ťaží, podľa podielu na blokoch za posledných 7 dní.
Opýtajte sa na tento miner. Overené účty sa pýtajú a odpovedajú, predajcovia odpovedajú za svoj obchod a každý príspevok pred zverejnením kontrolujeme.
Nguyen M. · 20. 10. 2026
what coolant goes in this thing? is tap water ok or do i need special stuff
AsicProfit SupportAsicProfit · 21. 10. 2026
Tap water is a bad idea: minerals and conductivity cause scale and corrosion inside the cold plates. Bitmain's guidance for the S21 XP Hyd family is deionized water or an approved antifreeze mix, pH around 8.5 to 9.5, very low conductivity at first fill, flow of roughly 8 to 10 litres per minute per miner and no more than 3.5 bar. Follow the manual that ships with your S21j XP Hyd if its numbers differ, and plan to flush and replace the coolant about once a year.
Mateusz K. · 18. 10. 2026
My loop sits outside and the water is around 10°C in winter. Will the miner start?
AsicProfit SupportAsicProfit · 18. 10. 2026
Probably not cleanly. Guidance for the S21 XP Hyd family says not to cold start with coolant inlet below 20°C, with a normal inlet range of about 20 to 50°C. In winter, bypass or slow the dry cooler until the loop warms up, and use an antifreeze mix if any pipes are exposed to frost. Check that the pump is running and the air is bled out before you power the hashboards on.
Connor W. · 13. 10. 2026
What's the real difference between the S21j XP Hyd 495T and the regular S21 XP Hyd 473T?
AsicProfit SupportAsicProfit · 13. 10. 2026
Mostly output per box. The S21j XP Hyd is listed at 495 TH/s and about 5,940 W, while the S21 XP Hyd is listed at 473 TH/s and about 5,676 W, so both sit near 12 J/TH. You get a little more hashrate per unit and per rack slot for a little more power. Both mine SHA-256 coins such as Bitcoin. Break-even depends mostly on your electricity price, so compare the two in the calculator on this page at your power price.
Tran B. · 6. 10. 2026
Is a hydro miner like this a sensible first machine for someone new to mining?
AsicProfit SupportAsicProfit · 7. 10. 2026
Experienced owners usually say no. A hydro unit adds plumbing, leak checks, coolant care, flushing and monitoring on top of the electrical work, and a failure in the cooling loop can damage the hardware quickly. If you have never run an air-cooled ASIC, start there or have the loop designed and commissioned by someone who has built one. Hydro makes most sense in a planned installation, ideally one that reuses the heat.
Mikkel J. · 28. 9. 2026
Do I need a dry cooler, or can I just put a car radiator outside?
AsicProfit SupportAsicProfit · 29. 9. 2026
You need something that can reliably reject close to 6 kW of heat around the clock, with a pump, filters, an expansion tank and the right fittings in a closed loop. A proper dry cooler or a plate heat exchanger into a heating system is the usual answer; a small radiator will let the inlet temperature creep up until the miner throttles. Size the cooler for full load plus some margin. Several owners only recommend hydro units when the heat can be reused, for example for space or water heating.
Oleh B. · 22. 9. 2026
Can I run the S21j XP Hyd at home off a normal wall socket?
AsicProfit SupportAsicProfit · 23. 9. 2026
No. It is listed at about 5,940 W at the wall, far more than a household socket can carry. Its sibling, the S21 XP Hyd, is specified for 380-415V three-phase input with a certified PDU and C20 power cable, and the S21j XP Hyd is sold for the same kind of supply. Plan a dedicated three-phase feed with correctly sized protection and good grounding, installed by an electrician, and confirm the input range on your unit's label before you buy.
Na položenie otázky sa prihláste overeným účtom. Prihlásiť sa