what coolant goes in this thing? is tap water ok or do i need special stuff
AsicProfit SupportAsicProfit · 2026年10月21日
Tap water is a bad idea: minerals and conductivity cause scale and corrosion inside the cold plates. Bitmain's guidance for the S21 XP Hyd family is deionized water or an approved antifreeze mix, pH around 8.5 to 9.5, very low conductivity at first fill, flow of roughly 8 to 10 litres per minute per miner and no more than 3.5 bar. Follow the manual that ships with your S21j XP Hyd if its numbers differ, and plan to flush and replace the coolant about once a year.
Mateusz K. · 2026年10月18日
My loop sits outside and the water is around 10°C in winter. Will the miner start?
AsicProfit SupportAsicProfit · 2026年10月18日
Probably not cleanly. Guidance for the S21 XP Hyd family says not to cold start with coolant inlet below 20°C, with a normal inlet range of about 20 to 50°C. In winter, bypass or slow the dry cooler until the loop warms up, and use an antifreeze mix if any pipes are exposed to frost. Check that the pump is running and the air is bled out before you power the hashboards on.
Connor W. · 2026年10月13日
What's the real difference between the S21j XP Hyd 495T and the regular S21 XP Hyd 473T?
AsicProfit SupportAsicProfit · 2026年10月13日
Mostly output per box. The S21j XP Hyd is listed at 495 TH/s and about 5,940 W, while the S21 XP Hyd is listed at 473 TH/s and about 5,676 W, so both sit near 12 J/TH. You get a little more hashrate per unit and per rack slot for a little more power. Both mine SHA-256 coins such as Bitcoin. Break-even depends mostly on your electricity price, so compare the two in the calculator on this page at your power price.
Tran B. · 2026年10月6日
Is a hydro miner like this a sensible first machine for someone new to mining?
AsicProfit SupportAsicProfit · 2026年10月7日
Experienced owners usually say no. A hydro unit adds plumbing, leak checks, coolant care, flushing and monitoring on top of the electrical work, and a failure in the cooling loop can damage the hardware quickly. If you have never run an air-cooled ASIC, start there or have the loop designed and commissioned by someone who has built one. Hydro makes most sense in a planned installation, ideally one that reuses the heat.
Mikkel J. · 2026年9月28日
Do I need a dry cooler, or can I just put a car radiator outside?
AsicProfit SupportAsicProfit · 2026年9月29日
You need something that can reliably reject close to 6 kW of heat around the clock, with a pump, filters, an expansion tank and the right fittings in a closed loop. A proper dry cooler or a plate heat exchanger into a heating system is the usual answer; a small radiator will let the inlet temperature creep up until the miner throttles. Size the cooler for full load plus some margin. Several owners only recommend hydro units when the heat can be reused, for example for space or water heating.
Oleh B. · 2026年9月22日
Can I run the S21j XP Hyd at home off a normal wall socket?
AsicProfit SupportAsicProfit · 2026年9月23日
No. It is listed at about 5,940 W at the wall, far more than a household socket can carry. Its sibling, the S21 XP Hyd, is specified for 380-415V three-phase input with a certified PDU and C20 power cable, and the S21j XP Hyd is sold for the same kind of supply. Plan a dedicated three-phase feed with correctly sized protection and good grounding, installed by an electrician, and confirm the input range on your unit's label before you buy.