What's the difference between the SealMiner A2 and the A2 Hydro?
AsicProfit SupportAsicProfit · 2026年10月21日
Bitdeer lists the air-cooled A2 at 226 TH/s and 3,729 W, and the A2 Hydro at up to 446 TH/s and 7,359 W, both at 16.5 J/TH. Efficiency is the same; the Hydro packs about twice the hashrate into a 2U rack unit but needs a water-cooling loop, pumps and a heat rejection system. The later A2 Pro models are a different, more efficient series, so check exactly which one a listing means.
Ivan G. · 2026年10月19日 · 別のバージョンについて
What coolant, flow and temperatures does the A2 Hyd need?
AsicProfit SupportAsicProfit · 2026年10月19日
Bitdeer's guide gives a coolant inlet of 20 to 55°C in normal mode and 20 to 45°C in high hash mode, at least 10.2 litres per minute, and inlet pressure no higher than 350 kPa. Use distilled water with corrosion inhibitor and antifreeze, stainless steel piping with no copper, a main filter of at least 100 mesh, a 3.5 bar relief valve and an expansion tank. Purge all air before powering on.
Mehmet Y. · 2026年10月14日 · 別のバージョンについて
How do I get an A2 onto my pool? Does it need special software?
AsicProfit SupportAsicProfit · 2026年10月15日
It uses DHCP by default. Bitdeer's Sealminer Tool finds the IP after you hold the IP Report button for about five seconds, then you log in from a browser with the default credentials in the manual and change them. Enter your pool URL and worker name; changes apply without a reboot. The same tool handles batch firmware upgrades and settings if you run several machines.
Sam P. · 2026年10月10日 · 別のバージョンについて
my circuit can't take full power, can I cap the A2's wattage?
AsicProfit SupportAsicProfit · 2026年10月11日
Yes. SealMiner firmware has Low Power, Normal and High Performance modes, plus a Custom mode where you set a maximum input power to suit your PDU or circuit. Bitdeer warns that if you set a high target hashrate with too little input power, the machine may throttle or become unstable, so lower both together or simply use the Low Power preset. Normal mode is the factory default.
Mikkel J. · 2026年10月3日 · 別のバージョンについて
Can I run the air-cooled A2 in my garage?
AsicProfit SupportAsicProfit · 2026年10月5日
Possibly, if the space suits a farm-class machine. It draws about 3.7 kW, all of which becomes heat that must be exhausted, and it needs a dedicated high-power circuit. Bitdeer advises keeping humidity under 60 percent and cleaning dust every three to six months. Check the input voltage range in the A2 user guide against your supply before buying.
Lukas W. · 2026年9月16日 · 別のバージョンについて
What can void the warranty on the hydro version?
AsicProfit SupportAsicProfit · 2026年9月17日
Bitdeer lists, among others: coolant or pipe materials that do not meet spec, a loop without an expansion tank or relief valve leading to overpressure, blockages from a system that was not cleaned properly, and wrong connectors. If a miner is disconnected from the loop, drain it within two hours, and fully drain it before storage or near freezing temperatures. Keep records of your coolant and commissioning.