Typical lowest price over 90 days: $8,823 – $9,176
OneMiners★ Featured✓ Verified sellerHalloween: $100 off minersHALLOWEEN100Extended warrantyPay in instalmentsIn stock, fast deliveryBitmain Antminer S23e Hyd 2U - 865 TH/s · In StockHost with them from $0.0364/kWh, $230 a monthShips from United States · checked 3 h ago
Yesmining✓ Verified sellerBitmain Antminer S23e Hydro 2U 865T Bitcoin MinerHost with them from $0.07/kWh, $442 a monthShips from China · checked 26 h ago
Antminer Distribution Europe✓ Verified sellerAntminer S23e Hyd 2U (865 th/s)Host with them from $0.065/kWh, $410 a monthShips from Netherlands · checked 19 h ago
The calculator from our free widget: every payback on this page follows it.
Income a day
$31.13
Power a day
−$7.56
Hosting a day
—
Profit a day
$23.57
Payback at $8,823
—
Profit and payback are estimates from today's coin prices and network difficulty, before pool fees, hosting and taxes. They change every day. Not financial advice.
Bitmain's Antminer S23e Hyd 2U is a 2U rack-mount hydro-cooled SHA-256 miner for BTC, BCH and BSV, released in April 2026. It delivers 865 TH/s at 8650 W, or 10 J/TH.
Profit by coin
Every coin this miner can mine, at today's prices and difficulty · $0.0364/kWh
Rankings use the algorithm's main coin (BTC for SHA-256, LTC + DOGE for Scrypt): small side chains may pay more per hash today but can't absorb much hashrate.
The Bitmain Antminer S23e Hyd 2U (865Th) is an ASIC miner by Bitmain for the SHA-256 algorithm, rated at 865 TH/s on 8,650 W. It came out in April 2026. At 10.0 J/TH it is 51% more efficient than the median SHA-256 miner we track (20.4 J/TH). At $0.036/kWh it ranks #5 of 299 SHA-256 miners by daily profit, earning about $23.57 a day mining BTC. The best price on AsicProfit is $8,823. At today's rates it would pay for itself in about 375 days. It is water-cooled (hydro), so it needs a cooling loop and a dry cooler instead of fans.
Questions and answers 6
Ask about this miner. Verified accounts ask and answer, sellers answer as their store, and every post is checked before it shows.
Ryan M. · Oct 26, 2026
What exact power does the S23e U2H take? 3-phase only?
AsicProfit SupportAsicProfit · Oct 26, 2026
Yes, three-phase only. Bitmain gives an AC input range of 342 to 528 V, a rated range of 380 to 480 V at 50 to 60 Hz, a maximum input current of 20 A and an LP34 power port. Typical draw is 8650 W at a 35 C coolant inlet. Wrong input voltage can damage the server, so have the electrical side done by a qualified electrician.
Petr S. · Oct 16, 2026
What coolant flow, temperature and pH does the S23e Hyd need?
AsicProfit SupportAsicProfit · Oct 17, 2026
Bitmain lists inlet coolant at 20 to 50 C (35 C typical), flow of 16 to 20 L/min, and pressure up to 3.5 bar. You can use antifreeze, deionized water or pure water, with pH targets of 7.0 to 9.0 for antifreeze, 8.5 to 9.5 for deionized water and 6.5 to 7.5 for pure water. The pipe connector is UQD08. Keep the loop clean and filtered.
Oleh B. · Sep 29, 2026
How long is the warranty on the S23e Hyd 2U compared to air-cooled Antminers?
AsicProfit SupportAsicProfit · Sep 30, 2026
Bitmain lists a 365-day warranty from the shipping date for the S23e U2H, longer than the 180 days it gives on several air-cooled models such as the KS7. The warranty applies to the original buyer who purchased directly from Bitmain. If you buy through a reseller, the reseller handles warranty, so get their terms in writing.
Anna S. · Sep 19, 2026
Will a 2U S23e fit in a normal server rack?
AsicProfit SupportAsicProfit · Sep 20, 2026
It is a 2U rack unit at 600 x 482.6 x 86 mm without packaging, so it fits standard 19 inch rack width, but you need enough depth for the chassis plus coolant connections and the power cable. Each unit weighs roughly 28 to 31 kg, so check your rack's load rating and use proper rails. Bitmain also sells racks and containers designed for these 2U hydro units.
Gabor N. · Sep 16, 2026
Can I run an S23e Hyd 2U at home or is it strictly for data centers?
AsicProfit SupportAsicProfit · Sep 17, 2026
It is built for racks and liquid-cooling infrastructure. Bitmain specifies three-phase power with a rated range of 380 to 480 V, about 8650 W per unit, and a coolant loop with 16 to 20 L/min of flow. Bitmain points to its container and dry-cooling tower manual for coolant handling. A home build is possible only with three-phase supply, a pump, heat exchanger and plumbing, so most buyers host it.
Jake T. · Sep 15, 2026
Anything special about storing or shipping an S23e Hyd between sites?
AsicProfit SupportAsicProfit · Sep 16, 2026
Yes. Bitmain warns that the server must be stored completely dry, with no coolant or water left inside, because residual liquid can cause corrosion, short circuits and permanent damage. Drain and dry the unit before storage or transport. Bitmain lists a storage temperature of -40 to 85 C and operating humidity of 10 to 90 percent, non-condensing.